Summary for Test 2021-12-22-24-1

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 215256
DEA: 100S7504
EFIS: 1014000099
DIST-CO-RTE-PM10-ALP,AMA,TUO-4,16,49,88,108,207-var
Award Date12/30/2020
Closeout Date12/05/2022
Work DescriptionREMOVE AND REPLACE DRAINAGE SYSTEMS.
Location DescriptionALPINE, AMADOR AND TUOLUMNE COUNTIES AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 11/02/2020)

Sample Information

Sample Taken Date12/22/2021 Sample Unique Key24
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/22/2022
Sample typeQuality Control A brief description of the sample4x8 concrete cylinders
The quantity of what the sample constitutesdays production From where was the sample collectedManufacturer
First name of sampler or witnessed by Jose Last name of sampler or witnessed bySanchez
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameForterra Pipe and Precast, Florin Rd Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numbermix 5
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected2
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBesser Hopper Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2021-12-22-24
DIME Test ID: 2021-12-22-24-1
Testing Lab: Rinker Materials
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2022-07-06

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Jose Sanchez
Date of test: 01/04/2022
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Maximum load on cylinder 1: 60435 lb
Maximum load on cylinder 2: 66105 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 13 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Compressive strength (to nearest 10 psi): 5040 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/6/2022