Summary for Test 2022-06-30-18-2
Test performed: CTM 217-June 2011Project Information
Project Identifiers | Project ID: 215364 DEA: 07333204 EFIS: 0716000301 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-.8/.8 |
Award Date | 09/08/2021 |
Closeout Date | 03/01/2023 |
Work Description | INSTALL SOLAR PV POWERED LIGHTING SYSTEM. |
Location Description | IN KERN COUNTY NEAR LEBEC AT VARIOUS LOCATIONS FROM OFF-RAMP OF NORTHBOUND REST AREA TO 0.1 MILE NORTH OF OFF-RAMP OF SOUTHBOUND REST AREA. |
QA Service Level | 1 (Verified on 07/12/2021) |
Sample Information
Sample Taken Date | 06/30/2022 | Sample Unique Key | 18 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/30/2022 |
Sample type | Acceptance | A brief description of the sample | WCS PCC Aggregate |
The quantity of what the sample constitutes | 40 CY | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Hopkins |
Title of sampler | Plant Inspector | Telephone number of sampler | 213-792-4793 |
Laboratory sample identification | KH105E | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | ALPINE READY MIX | Transportation Laboratory (TL) Number | C063022C |
Inspector Lot Number from the Transportation Laboratory (TL) Form | KH105E | Structure unique identifier | |
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-15-0041 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Concrete Barrier | The fabricator/manufacturer designation for the sample | |
The plant number | Alpine Ready Mix Frazier Park | A detailed description of where the material sample was collected | Conveyor Belt |
Where the material sample would have been placed if not sampled | Concrete Barrier | Primary Aggregate Nominal Size | fine |
The concrete mix design number | CTCL1717 | Lot number | |
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2022-06-30-18
DIME Test ID: 2022-06-30-18-2
Testing Lab: CT D07 - Plant Services
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2022-07-08
Test Results
Number of tests: 2
Input Type: Measured
Tester's full name: Kevin Hopkins
Date of test: 07/01/2022
Temperature correction: 0
Temperature of solution: 75
Clay reading (test 1): 46
Sand reading (test 1): 39
Clay reading (test 2): 47
Sand reading (test 2): 40
Sand equivalent (test 1): 85
Sand equivalent (test 2): 86
Sand equivalent before temperature correction: 86
Sand equivalent after temperature correction: 86
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/8/2022 ✔