Summary for Test 2022-06-09-49-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 215364
DEA: 07333204
EFIS: 0716000301
DIST-CO-RTE-PM07-LA-5-.8/.8
Award Date09/08/2021
Closeout Date03/01/2023
Work DescriptionINSTALL SOLAR PV POWERED LIGHTING SYSTEM.
Location DescriptionIN KERN COUNTY NEAR LEBEC AT VARIOUS LOCATIONS FROM OFF-RAMP OF NORTHBOUND REST AREA TO 0.1 MILE NORTH OF OFF-RAMP OF SOUTHBOUND REST AREA.
QA Service Level1 (Verified on 07/12/2021)

Sample Information

Sample Taken Date06/09/2022 Sample Unique Key49
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/09/2022
Sample typeAcceptance A brief description of the sample1" X #4
The quantity of what the sample constitutes40 CY From where was the sample collectedSupplier
First name of sampler or witnessed byKevin Last name of sampler or witnessed byHopkins
Title of samplerPlant Inspector Telephone number of sampler213-792-4793
Laboratory sample identificationKH103C Linked DIME Sample ID
The fabricator/manufacturer/facility nameALPINE READY MIX Transportation Laboratory (TL) NumberC060922A
Inspector Lot Number from the Transportation Laboratory (TL) FormKH103C Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-15-0041
The fabricator's/manufacturer's product name for the sampleConcrete Barrier The fabricator/manufacturer designation for the sample
The plant numberAlpine Ready Mix Frazier Park A detailed description of where the material sample was collectedConveyor Belt
Where the material sample would have been placed if not sampledConcrete Barrier Primary Aggregate Nominal Size1 inch
The concrete mix design numberCTCL1717 Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2022-06-09-49
DIME Test ID: 2022-06-09-49-1
Testing Lab: CT D07 - Plant Services
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2022-07-13

Test Results


What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Kevin Hopkins
Date of test: 06/15/2022
Cumulative Mass RetainedCumulative Percent Passing
13130 grams
0 grams100 %
330 grams97 %
3360 grams74 %
8520 grams35 %
10260 grams22 %
12600 grams4 %
12770 grams3 %
13130 grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/13/2022