Summary for Test 2022-06-28-22-2
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 214991 DEA: 044G2104 EFIS: 0412000310 |
---|---|
DIST-CO-RTE-PM | 04-NAP-121-0.5/1 |
Award Date | 05/19/2021 |
Closeout Date | Not set |
Work Description | WIDEN ROADWAY WITH HMA & REPLACE CULVERT WITH STRUCTURAL CONC BRIDGE. |
Location Description | NAPA COUNTY NEAR NAPA FROM 0.2 MILE SOUTH TO 0.3 MILE NORTH OF HUICHICA CREEK BRIDGE |
QA Service Level | 1 (Verified on 10/19/2020) |
Sample Information
Sample Taken Date | 06/28/2022 | Sample Unique Key | 22 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/01/2022 |
Sample type | Quality Assurance | A brief description of the sample | 4x8 concrete cylinders |
The quantity of what the sample constitutes | 3 Cylinders | From where was the sample collected | Job Site |
First name of sampler or witnessed by | NANA | Last name of sampler or witnessed by | Budu |
Title of sampler | Unknown | Telephone number of sampler | 510-867-4517 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Syar Concrete | Transportation Laboratory (TL) Number | 28 - Napa |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | 21-0118 |
Structure name | Abutment 1 CIDH and TANGENT Piles |
Material Information
Material Type | Concrete | The concrete mix design number | CT072CR8D4 |
---|---|---|---|
The truck number from where the sample was collected | 1106 | The batch plant ticket number from where the sample was collected | 886004542 |
Concrete batch plant | SYAR Concrete | The fabricator/manufacturer designation for the sample | SYAR Concrete |
A detailed description of where the material sample was collected | Back of truck chute | Where the material sample would have been placed if not sampled | Abut 1 TANGENT Piles 2 4 and 9 |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2022-06-28-22
DIME Test ID: 2022-06-28-22-2
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2022-07-05
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: SA
Date of test: 07/05/2022
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 4.01 in
Average diameter of cylinder 2: 4.01 in
Average diameter of cylinder 3: 4.02 in
Maximum load on cylinder 1: 55060 lbf
Maximum load on cylinder 2: 52077 lbf
Maximum load on cylinder 3: 58462 lbf
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Age of specimen: 7 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 12.63 in^2
Cross sectional area of cylinder 2: 12.63 in^2
Cross sectional area of cylinder 3: 12.69 in^2
Compressive strength of cylinder 1: 4360.0 psi
Compressive strength of cylinder 2: 4124.0 psi
Compressive strength of cylinder 3: 4606 psi
Compressive strength (to nearest 10 psi): 4360 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for Cylinder Code 1 of 3
Source: Bluehill Data Point File
Test graph for Cylinder Code 2 of 3
Source: Bluehill Data Point File
Test graph for Cylinder Code 3 of 3
Test was verified on 7/5/2022 ✔