Summary for Test 2022-06-16-35-5

Test performed: AASHTO T313-19

Project Information

Project IdentifiersProject ID: 993603
DEA: 051N7004
EFIS: 0521000081
DIST-CO-RTE-PM05-SLO-166-16.0/21.0
Award Date04/22/2022
Closeout Date03/28/2023
Work DescriptionPARTIAL DEPTH RECYCLING AND OVERLAY WITH RHMA (GAP GRADED).
Location DescriptionSAN LUIS OBISPO COUNTY ABOUT 8 MILES EAST OF SANTA MARIA FROM 0.5 MILE WEST OF HUASNA RIVER BRIDGE TO 1.9 MILES WEST OF CUYAMA RIVER BRIDGE.
QA Service Level1 (Verified on 03/28/2022)

Sample Information

Sample Taken Date06/16/2022 Sample Unique Key35
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/24/2022
Sample typeAcceptance A brief description of the sampleRhma-g w/ LIME PG64-16
The quantity of what the sample constitutes1 Can From where was the sample collectedSource
First name of sampler or witnessed by_ Last name of sampler or witnessed byPapich
Title of samplerQC Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSierra Pacific Materials Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeYes
Multigrade TypePG 64-16 / PG 64-10 Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2022-06-16-35
DIME Test ID: 2022-06-16-35-5
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Test Release Date: 2022-07-06

Test Results


Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 07/01/2022
Minimum test bath temperature at 240 s: -6.0 C
Maximum test bath temperature at 240 s: -6.1 C
Time of test load application: 11:00:04 HH:MM:SS
File name of test data: no data
Time beam in bath: no data
Time test started: no data
Flags issued by software during test: no data
Correlation coefficient (R²): 0
Regression coefficient a: no data
Regression coefficient b: no data
Regression coefficient c: no data
Load at time 0.0: 0.0 mN
Deflection at time 0.0 s: 0.000 µm
Load at time 0.5 s: 0.0 mN
Deflection at time 0.5 s: 0.000 µm
Load at 60.0 s: 992.0 mN
Beam deflection 60.0 s: 0.214 µm
Measured Stiffness Modulus 60.0 s: 372.000 mPa
Estimated Stiffness Modulus 60.0 s: 373.000 mPa
Difference between stiffness moduli 60.0 s: 0.27 %
Estimated m-value 60.0 s: 0.347
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/6/2022