Summary for Test 2022-06-16-39-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 214573
DEA: 073096U4
EFIS: 0719000091
DIST-CO-RTE-PM07-LA-210-R0.0/R9.7
Award DateNot set
Closeout DateNot set
Work DescriptionPLACE CONCRETE PAVEMENT, BARRIER, HMA, DRAINAGE, AND ELECTRICAL.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES FROM INTERSTATE 5 TO WHEATLAND AVENUE UNDERCROSSING
QA Service Level1 (Verified on 06/05/2020)

Sample Information

Sample Taken Date06/16/2022 Sample Unique Key39
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/20/2022
Sample typeDepartment Acceptance A brief description of the sample1/2" RHMA-G 326120 SVA3 VLO
The quantity of what the sample constitutes750 Tons From where was the sample collectedManufacturer
First name of sampler or witnessed byChris Last name of sampler or witnessed byS2 QC
Title of samplerS2 Technician Telephone number of sampler
Laboratory sample identification22-0155 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Materials Company Sun Valley Transportation Laboratory (TL) Number061622
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number
Sublot number HMA Mix NumberNot set

Test Details

DIME Sample ID: 2022-06-16-39
DIME Test ID: 2022-06-16-39-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2022-06-29

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Daniel Gomez
Date of test: 06/22/2022
Test procedure used?: Method A
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 1524.2 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 1404.9 g
Correction Factor (Percent by mass of HMA Specimen): 0.38 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 1000.4 F
Corrected Asphalt Binder Content: 7.45 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/29/2022