Summary for Test 2022-05-11-54-5
Test performed: CTM 521-June 2020Project Information
Project Identifiers | Project ID: 993235 DEA: 051H4504 EFIS: 0516000075 |
---|---|
DIST-CO-RTE-PM | 05-SB-154-R31.8/R32.1 |
Award Date | 11/22/2021 |
Closeout Date | Not set |
Work Description | CONSTRUCT CIDH CONCRETE PILES AND STRUCTURAL CONCRETE BRIDGE. |
Location Description | SANTA BARBARA COUNTY IN AND NEAR SANTA BARBARA FROM PRIMAVERA ROAD UNDERCROSSING TO LA COLINA ROAD UNDERCROSSING |
QA Service Level | 1 (Verified on 10/06/2021) |
Sample Information
Sample Taken Date | 05/11/2022 | Sample Unique Key | 54 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/12/2022 |
Sample type | Quality Control | A brief description of the sample | Concrete Cylinder |
The quantity of what the sample constitutes | 45cy | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Paul | Last name of sampler or witnessed by | Pastora |
Title of sampler | QC Inspector | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CEMEX Santa Barbara | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Rte154 La Colina Rd Overpass SW CIDH pile at ABUT 1 |
Material Information
Material Type | Concrete | The concrete mix design number | 1610898 |
---|---|---|---|
The truck number from where the sample was collected | 10070510 | The batch plant ticket number from where the sample was collected | 30234576 |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Back of Truck | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2022-05-11-54
DIME Test ID: 2022-05-11-54-5
Testing Lab: RMA Group - Rancho Cucamonga
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2022-06-21
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Jacob Bailey
Date of test: 06/08/2022
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 149230 lb
Maximum load on cylinder 2: 141450 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 5120 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/21/2022 ✔