Summary for Test 2022-06-17-18-2
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 215183 DEA: 101C1704 EFIS: 1014000144 |
---|---|
DIST-CO-RTE-PM | 10-MER-99-R12.7/17.8 |
Award Date | 01/22/2021 |
Closeout Date | Not set |
Work Description | RECONSTRUCT ROADWAY WITH ROADWAY EXCAVATION, PLACE HMA AND CRCP. |
Location Description | MERCED COUNTY IN MERCED FROM 0.2 MILE SOUTH OF CHILDS AVENUE OVERCROSSING TO 0.2 MILE SOUTH OF FRANKLIN ROAD OVERCROSSING. |
QA Service Level | 1 (Verified on 10/20/2020) |
Sample Information
Sample Taken Date | 06/17/2022 | Sample Unique Key | 18 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/20/2022 |
Sample type | Quality Assurance | A brief description of the sample | 3/4 HMA-A |
The quantity of what the sample constitutes | 4 boxes | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Billy | Last name of sampler or witnessed by | Cardenas |
Title of sampler | Lab Technician | Telephone number of sampler | |
Laboratory sample identification | 22-0H-60 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Teichert Materials Vernalis | Transportation Laboratory (TL) Number | MC220027 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 1 |
Sublot number | 11 | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2022-06-17-18
DIME Test ID: 2022-06-17-18-2
Testing Lab: CT D10 - District 10 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-04-19
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Hans Camenzind
Date of test: 06/21/2022
Test procedure used?: no data
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 0.22 %
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 4.61 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/19/2023 ✔