Summary for Test 2022-06-05-11-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 214573
DEA: 073096U4
EFIS: 0719000091
DIST-CO-RTE-PM07-LA-210-R0.0/R9.7
Award DateNot set
Closeout DateNot set
Work DescriptionPLACE CONCRETE PAVEMENT, BARRIER, HMA, DRAINAGE, AND ELECTRICAL.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES FROM INTERSTATE 5 TO WHEATLAND AVENUE UNDERCROSSING
QA Service Level1 (Verified on 06/05/2020)

Sample Information

Sample Taken Date06/05/2022 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/05/2022
Sample typeDepartment Acceptance A brief description of the sampleJPCP-RSC Beams
The quantity of what the sample constitutes1461 CY From where was the sample collectedJob Site
First name of sampler or witnessed byMichelangelo Last name of sampler or witnessed bySese
Title of samplerTET Telephone number of sampler310-345-6204
Laboratory sample identification22-1346 Linked DIME Sample ID
The fabricator/manufacturer/facility nameFlatiron Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design number3215-JPCPRSC-12
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedLast Load
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedDischarge from concrete truck into wheelbarrow. Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2022-06-05-11
DIME Test ID: 2022-06-05-11-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2022-06-16

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Michelangelo Sese
Date of test: 06/15/2022
Identification number: 22-1346
Width of specimen: 6 inch
Width of specimen 2: 6.1875 inch
Width of specimen 3: 6 inch
Depth of specimen: 6.125 inch
Depth of specimen 2: 6 inch
Depth of specimen 3: 6 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 9080 lb
Maximum load applied 2: 8610 lb
Maximum load applied 3: 8530 lb
Curing history and apparent moisture condition of the specimen: Yes
If specimen was capped, ground or if leather shims were used: NA
Defects in specimen, including numbers of beams discarded during test: None
Age of specimen: 10 days
Age of specimen in hours: no data
Modulus of rupture: 760 psi
Modulus of rupture 2: 730 psi
Modulus of rupture 3: 750 psi
Modulus of rupture average: 750 psi
General comments (publicly viewable) (Max 1000 characters): WB Rte. 210 Various Locations

Test was verified on 6/16/2022