Summary for Test 2022-05-24-32-2
Test performed: AASHTO T84-14Project Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 05/24/2022 | Sample Unique Key | 32 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/01/2022 |
Sample type | Verification | A brief description of the sample | 1/2" RHMA-G, WMA, PG 64-16 |
The quantity of what the sample constitutes | 5 Bags | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Erika | Last name of sampler or witnessed by | Gonzalez |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | 22-JMFPP-0078 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Pleasonton | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-01-0010 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | 326122 | |
The plant number | A detailed description of where the material sample was collected | Belt Cut at Plant | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2022-05-24-32
DIME Test ID: 2022-05-24-32-2
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2022-06-08
Test Results
Input Type: Measured
Tester's full name: Bang Nguyen
Date of test: 06/08/2022
Mass of saturated surface dry sample (before pycnometer) (S): 500.3 grams
Mass of the pycnometer with water and aggregate (C): 983.9 grams
Mass of the pycnometer with water (B): 670.8 grams
Mass of the oven dried sample (before pycnometer) (A): 490.8 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500.3 grams
Mass of the oven dry aggregate (for absorption) (A): 490.8 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.622
Bulk specific gravity (SSD Basis): 2.673
Apparent specific gravity: 2.762
Absorption: 1.9 %
General comments (publicly viewable) (Max 1000 characters): Bulk specific gravity (SSD) of fine aggregate - Bulk specific gravity of fine aggregate - Bulk specific gravity of fine aggregate - Apparent specific gravity of supplemental fines - Absorption of fine aggregate.
Test was verified on 6/8/2022 ✔