Test performed: AASHTO T315-20

Project Information

Project IdentifiersProject ID: 55556
DEA: OCR
EFIS: OCR
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Oregon Corp. Research.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date04/27/2022 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/11/2022
Sample typeProficiency A brief description of the samplePG76-22M sample 325
The quantity of what the sample constitutes1 Can From where was the sample collectedFabricator
First name of sampler or witnessed byOREGON COOP Last name of sampler or witnessed byOREGON COOP
Title of samplersample 325 Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameOREGON COOP Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 76-22 M
ModifiedYes Lot number
Sublot number Tank number
Time of sample HMA SupplierMcCall Terminals
Certified Asphalt SupplierOregon Corp - Salem OR MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2022-04-27-27
DIME Test ID: 2022-04-27-27-8
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-05-19

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 05/17/2022
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 20.534 kPa
Phase Angle (δ) (for the 10 cycles): 50.1 degree
Complex Modulus (G*) (for the 10 measurements): 2053.573 kPa
Test Temperature (Specimen 1): 31.0 C
(G*) x sin(δ)=: 1575 kPa
General comments (publicly viewable) (Max 1000 characters): PAV

Test was verified on 5/19/2022