Summary for Test 2022-04-29-23-2
Test performed: AASHTO T315-20Project Information
Project Identifiers | Project ID: 215621 DEA: 010J8704 EFIS: 0119000117 |
---|---|
DIST-CO-RTE-PM | 01-MEN-101,271-VAR |
Award Date | 05/14/2021 |
Closeout Date | 10/20/2022 |
Work Description | PLACE HMA, POLYESTER CONCRETE OVERLAY AND COLD PLANE. |
Location Description | MENDOCINO COUNTY AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 04/07/2021) |
Sample Information
Sample Taken Date | 04/29/2022 | Sample Unique Key | 23 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/03/2022 |
Sample type | Department Acceptance | A brief description of the sample | binder |
The quantity of what the sample constitutes | 1 can | From where was the sample collected | Source |
First name of sampler or witnessed by | C | Last name of sampler or witnessed by | Malik |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Valero - Benicia | Transportation Laboratory (TL) Number | 750503 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 58-22 |
---|---|---|---|
Modified | Lot number | ||
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2022-04-29-23
DIME Test ID: 2022-04-29-23-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-05-05
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Juan Gomez
Date of test: 05/05/2022
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.275 kPa
Phase Angle (δ) (for the 10 cycles): 83.8 degree
Complex Modulus (G*) (for the 10 measurements): 2.294 kPa
Test Temperature (Specimen 1): 58.0 C
Dynamic Shear, G*/sin(δ): 2.31 kPa
General comments (publicly viewable) (Max 1000 characters): re-test, 2nd sample
Test was verified on 5/5/2022 ✔