Summary for Test 2022-04-08-36-5
Test performed: AASHTO T176-08Project Information
Project Identifiers | Project ID: 214486 DEA: 080K1224 EFIS: 0815000244 |
---|---|
DIST-CO-RTE-PM | 08-SBD-15-R28.6/37.5 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | REHBILIATATE EXISTING MAINLINE AND RAMP PAVEMENT |
Location Description | SAN BERNARDINO COUNTY IN HESPERIA AND VICTORVILLE FROM OAK HILL ROAD OVERCROSSING TO 0.1 MILE SOUTH OF BEAR VALLEY ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 06/23/2021) |
Sample Information
Sample Taken Date | 04/08/2022 | Sample Unique Key | 36 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/13/2022 |
Sample type | Verification | A brief description of the sample | JMF 1" HMA-A-SP R25 1.0% LSM |
The quantity of what the sample constitutes | 3 Bags LSM, 8 Bags Agg., 2 Bags Rap | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Blue Diamond | Last name of sampler or witnessed by | QC |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0228A-22 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Blue Diamond-Victorville | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-36-0046,91-36-0106 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | 300222 WM R25 | A detailed description of where the material sample was collected | Belt Cut at Blue Diamond Victorville Plant |
Where the material sample would have been placed if not sampled | Asphalt Paving | Primary Aggregate Nominal Size | 1 inch |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2022-04-08-36
DIME Test ID: 2022-04-08-36-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2022-05-13
Test Results
How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Md Tarafder
Date of test: 04/18/2022
Clay Level (Test 1): 5.2
Sand Level (Test 1): 3.9
Clay Level (Test 2): 5.3
Sand Level (Test 2): 4
Clay Level (Test 3): 5.1
Sand Level (Test 3): 4
Sand Equivalent (Test 1): 75
Sand Equivalent (Test 2): 76
Sand Equivalent (Test 3): 79
Sand Equivalent: 77
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/13/2022 ✔