Summary for Test 2016-05-31-12-3
Test performed: ASTM A370-15Project Information
Project Identifiers | Project ID: 208682 DEA: 083401U4 EFIS: 0800000609 |
---|---|
DIST-CO-RTE-PM | 08-SBD-138,138-6.2/6.4,2.3/R15.2 |
Award Date | 09/10/2014 |
Closeout Date | 06/23/2021 |
Work Description | WIDEN TO 4 LNS FR BEEKLEY RD TO JCT 15, ADD 1 LN EB FR PHELAN RD TO |
Location Description | SAN BERNARDINO COUNTY ON ROUTE 138 NEAR PHELAN FROM 0.6 MILE WEST OF PHELAN ROAD TO THE JUNCTION OF ROUTE 15 AND ON ROUTE 2 FROM 0.1 MILE NORTH OF WILD HORSE CANYON ROAD TO ROUTE 138 |
QA Service Level | 1 (Verified on 03/11/2013) |
Sample Information
Sample Taken Date | 05/31/2016 | Sample Unique Key | 12 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/03/2016 |
Sample type | Quality Assurance | A brief description of the sample | Ductile Iron Casting |
The quantity of what the sample constitutes | 128 | From where was the sample collected | Source |
First name of sampler or witnessed by | Debbie | Last name of sampler or witnessed by | Ozuna |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Dotson iron casting | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM6 - Ductile Iron Cast Samples | Heat Number (s) | 1466, 1476 |
---|---|---|---|
Part Number (s) | 68 19 246 | Material Specification | A536 |
Grades | 65-45-12 | Metal Foundry Manufacturer (Mill) | Dotson iron casting |
Prestressing Manufacturer | Dywidag Systems |
Test Details
DIME Sample ID: 2016-05-31-12
DIME Test ID: 2016-05-31-12-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2016-06-08
Test Results
Number of Samples: 4
Input Type: Calculated
Tester's full name: Arnold
Date of test: 06/07/2016
UTM: 67KIP
Temperature: 71 F
Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1466 | 0.498 | 0.1948 | 50671 | 86790 | 14.4 | Arnold | |
2 | 1466 | 0.498 | 0.1948 | 48976 | 80960 | 15.4 | Arnold | |
3 | 1476 | 0.4975 | 0.1944 | 48185 | 79550 | 13.8 | Arnold | |
4 | 1476 | 0.498 | 0.1948 | 47235 | 78780 | 14.5 | Arnold |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Test was verified on 6/8/2016 ✔