Summary for Test 2022-03-25-28-6
Test performed: CTM 217-June 2011Project Information
Project Identifiers | Project ID: 66666 DEA: APP EFIS: 0019000052 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 03/25/2022 | Sample Unique Key | 28 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/23/2022 |
Sample type | Aggregate Prequalification Program | A brief description of the sample | Washed Concrete Sand |
The quantity of what the sample constitutes | 6 Buckets | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Anthony | Last name of sampler or witnessed by | Myers |
Title of sampler | QC Supervisor | Telephone number of sampler | 559-477-6228 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Cemex Rockfield | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-10-0014 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Stockpile | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | fine | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2022-03-25-28
DIME Test ID: 2022-03-25-28-6
Testing Lab: CEMEX - Rockfield
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2022-04-26
Test Results
Number of tests: 3
Input Type: Calculated
Tester's full name: Anthony Myers
Date of test: 03/25/2022
Temperature correction: 0
Temperature of solution: 73
Clay reading (test 1): 47
Sand reading (test 1): 42
Clay reading (test 2): 46
Sand reading (test 2): 41
Clay reading (test 3): 47
Sand reading (test 3): 41
Sand equivalent (test 1): 90
Sand equivalent (test 2): 90
Sand equivalent (test 3): 88
Sand equivalent before temperature correction: 90
Sand equivalent after temperature correction: 90
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/26/2022 ✔