Summary for Test 2022-03-29-3-11
Test performed: ASTM B499-09r21Project Information
Project Identifiers | Project ID: 993131 DEA: 010A1104 EFIS: 0112000211 |
---|---|
DIST-CO-RTE-PM | 01-HUM-101-27.7 |
Award Date | 09/21/2021 |
Closeout Date | Not set |
Work Description | BRIDGE SEISMIC RETROFIT AND ROCK SLOPE PROTECTION. |
Location Description | HUMBOLDT COUNTY NEAR MYERS FLAT AT SOUTH FORK EEL RIVER BRIDGE |
QA Service Level | 1 (Verified on 07/22/2021) |
Sample Information
Sample Taken Date | 03/29/2022 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/06/2022 |
Sample type | Quality Control | A brief description of the sample | 1-1/8"x5-3/4" A325 Bolts |
The quantity of what the sample constitutes | 135 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Oscar | Last name of sampler or witnessed by | Vizcaino |
Title of sampler | Telephone number of sampler | 6787558969 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | St Louis Screw and Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT0151870 |
---|---|---|---|
Heat Number(s) | 20358600 | Nut Mfg. Lot Number(s) | 32858-201231 |
Washer Mfg. Lot Number(s) | 1221-158 | Bolt Specification | ASTM A325-1 |
Bolt Length(s) | 5-3/4" | Nut Specification | ASTM A563 DH |
Washer Specification | ASTM F436-1 | Finish | ASTM B695 - Mech Galv |
Diameter/Size | 1-1/8" | Bolt Mfg. Lot Number | BM0303 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2022-03-29-3
DIME Test ID: 2022-03-29-3-11
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2022-04-28
Test Results
Input Type: Calculated
Tester's full name: Steven Paine
Date of test: 04/22/2022
Sample No.: 1C
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: BM0303
Finish Coating: ASTM B695 - Mech Galv
Product Markings: A325 USA SL
Size: 1.125 in
Bolt Length: 5.75 in
Measurement Average: 2.19 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/28/2022 ✔