Summary for Test 2022-04-11-3-6
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 993169 DEA: 050A0904 EFIS: 0513000028 |
---|---|
DIST-CO-RTE-PM | 05-MON-156-R1.4/R2.0 |
Award Date | 12/14/2021 |
Closeout Date | Not set |
Work Description | WIDEN REINFORCED STRUCTURAL CONCRETE BRIDGE & REPLACE BRIDGE RAILING. |
Location Description | MONTEREY COUNTY IN AND NEAR CASTROVILLE FROM 0.3 MILE EAST OF ROUTE 156/183 SEPARATION TO 0.2 MILE EAST OF CASTROVILLE BOULEVARD |
QA Service Level | 1 (Verified on 08/17/2021) |
Sample Information
Sample Taken Date | 04/11/2022 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/18/2022 |
Sample type | Quality Assurance | A brief description of the sample | #6 x 2'-8" Hoops |
The quantity of what the sample constitutes | 8 hoops from lot 1 thru 5 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Osiel | Last name of sampler or witnessed by | Ramirez |
Title of sampler | Quality Assurance Inspector | Telephone number of sampler | 5599740870 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | TNT Rebar Company | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L123-021-22 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 1201039695 |
Hoop Manufacturer Lot Number(s) | Lots 1 and 4 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | #6 |
Diameter of Hoop | 2'-8" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Nucor Cascade |
Welding Company | TNT Rebar Cmpany | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2022-04-11-3
DIME Test ID: 2022-04-11-3-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2022-04-21
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 04/21/2022
UTM: 400kip
Temperature: 72 f
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 3 | 4 | 6/19mm | 0.44 | 39870.33 | 90614 | Ok Necking | bewing |
General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 4/21/2022 ✔