Summary for Test 2022-03-08-30-3
Test performed: AASHTO T315-20Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 03/08/2022 | Sample Unique Key | 30 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/15/2022 |
Sample type | Verification | A brief description of the sample | Tank 2B |
The quantity of what the sample constitutes | 2 of 2, split sample | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Severino | Last name of sampler or witnessed by | Gorospe |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 1220301326 | Linked DIME Sample ID | 2022-03-08-28 |
The fabricator/manufacturer/facility name | Benicia, CA | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 58-22 |
---|---|---|---|
Modified | Lot number | ||
Sublot number | Tank number | 2B | |
Time of sample | 0600 | HMA Supplier | |
Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2022-03-08-30
DIME Test ID: 2022-03-08-30-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-04-20
Test Results
Phase: PAV residue
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 04/19/2022
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 68.313 kPa
Phase Angle (δ) (for the 10 cycles): 41.3 degree
Complex Modulus (G*) (for the 10 measurements): 6830.330 kPa
Test Temperature (Specimen 1): 22.0 C
(G*) x sin(δ)=: 4508 kPa
General comments (publicly viewable) (Max 1000 characters): PAV
Test was verified on 4/20/2022 ✔