Summary for Test 2016-05-26-3-6
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 211049 DEA: 100Y1004 EFIS: 1013000268 |
---|---|
DIST-CO-RTE-PM | 10-STA-99-R11.7/R15.0 |
Award Date | 02/22/2016 |
Closeout Date | 04/11/2017 |
Work Description | INSTALL DOUBLE LUMINAIRE. |
Location Description | IN STANISLAUS COUNTY IN AND NEARCERES FROM NORTH STREET UNDERCROSSING TO TUOLUMNE RIVER BRIDGE |
QA Service Level | 1 (Verified on 03/24/2016) |
Sample Information
Sample Taken Date | 05/26/2016 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/27/2016 |
Sample type | Quality Assurance | A brief description of the sample | Flash Welded Rebar Hoops |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Thompson |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Harris Salinas | Transportation Laboratory (TL) Number | C740269 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B905216 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 582535 |
Hoop Manufacturer Lot Number(s) | H08 H09 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 4 |
Diameter of Hoop | 1'-8" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Harris Salinas |
Welding Company | Harris Rebar | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2016-05-26-3
DIME Test ID: 2016-05-26-3-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-06-02
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 05/31/2016
UTM: 75KIP
Temperature: 70 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 3 | H09 | #4/13mm | 0.2 | 18587 | 92940 | necking okay | Fred |
General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
WARNING: No graph data imported from Instron machine.
Test was verified on 6/2/2016 ✔