Summary for Test 2022-01-06-60-1

Test performed: CTM 214-August 2010

Project Information

Project IdentifiersProject ID: 214995
DEA: 040J5304
EFIS: 0414000010
DIST-CO-RTE-PM04-ALA-880-11.4/12.2
Award Date01/04/2021
Closeout Date04/26/2023
Work DescriptionPATTERSON SLOUGH BRIDGE DECK REHAB
Location DescriptionALAMEDA COUNTY IN FREMONT FROM 0.4 MILE SOUTH TO 0.4 MILE NORTH OF PATTERSON SLOUGH BRIDGE
QA Service Level1 (Verified on 10/19/2020)

Sample Information

Sample Taken Date01/06/2022 Sample Unique Key60
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/22/2022
Sample typeAnnual Source Testing A brief description of the sampleCoarse Aggregate
The quantity of what the sample constitutes4 bags From where was the sample collectedSource
First name of sampler or witnessed byCurtis Last name of sampler or witnessed byGilbert
Title of samplerPlant Telephone number of sampler
Laboratory sample identification22-PCCC-0052 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Pleasanton Transportation Laboratory (TL) NumberC728226
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-01-0010
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2022-01-06-60
DIME Test ID: 2022-01-06-60-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Test Release Date: 2022-04-15

Test Results


What size aggregate is being tested?: Coarse Aggregate
Input Type: Calculated
Tester's full name: Ryan Kester/ Jay Horton
Date of test: 04/15/2022
Percentage Loss of material retained on 2 x 1 ½ in. sieve: no data
Percentage Loss of material retained on 1 ½ x 1 in. sieve: no data
Percentage Loss of material retained on 1 x ¾ in. sieve: no data
Percentage Loss of material retained on ¾ x ½ in. sieve: no data
Percentage Loss of material retained on ½ x ⅜ in. sieve: no data
Percentage Loss of material retained on ⅜ in. x #4 sieve: no data
Percentage Loss of material retained on 2 in. through 1 1/2 in. sieve: no data
Percentage Loss of material retained on 1 in. through 3/4 in. sieve: no data
Percentage Loss of material retained on 3/4 in. through #4 sieve: no data
Weighted Average Percent Loss of Coarse Aggregate: 2.9 %
Batch Soundness Loss of Coarse Aggregate (2 1/2 in maximum): no data
Batch Soundness Loss of Coarse Aggregate (1 1/2 in maximum): no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/15/2022