Summary for Test 2016-05-12-8-32
Test performed: ASTM A416-15Project Information
Project Identifiers | Project ID: 8196 DEA: 59912684 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | |
Location Description | |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 05/12/2016 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/23/2016 |
Sample type | Quality Assurance | A brief description of the sample | .6in Prestressing Strand |
The quantity of what the sample constitutes | 75 | From where was the sample collected | Source |
First name of sampler or witnessed by | Don | Last name of sampler or witnessed by | Hiranaga |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Sumiden | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM4 - Prestressing Strand | Comments | Unknown |
---|---|---|---|
Reel/Coil/Pack Number(s) | Number of Coils | Unknown | |
Group Number | 10845 | Strand Diameter | |
Grade | 270 | Strand Specification | ASTM A 416 |
Heat Number(s) | S0285101, S0285103, S0285106, S0285639, S0285640, S0518616, S0525015-2, S0525615, S0525815, S0525915, S0526015, S0526315,, S0526515, S0529916, S0533115-2, S0584315, S0585115, S0598315-2 | Mfg. Lot Number(s) | NA |
Manufacturer(s) | Sumiden |
Test Details
DIME Sample ID: 2016-05-12-8
DIME Test ID: 2016-05-12-8-32
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2016-05-27
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 05/26/2016
UTM: 120KIP
Temperature: 70 F
Extensometers: E88766
Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | S0598315-2 | S377448-5 | 0.21 | 60483 | 55559 | 28.8 | 1.89 | Brian |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 5/27/2016 ✔