Summary for Test 2022-02-26-5-9
Test performed: AASHTO T315-20Project Information
Project Identifiers | Project ID: 993153 DEA: 120H0474 EFIS: 1212000053 |
---|---|
DIST-CO-RTE-PM | 12-ORA-241-27.8/38.0 |
Award Date | 10/21/2021 |
Closeout Date | Not set |
Work Description | PLACE HMA AND PERFORATED PLASTIC PIPE UNDERDRAIN. |
Location Description | ORANGE COUNTY AT VARIOUS LOCATIONS FROM 0.1 MILE NORTH OF ROUTE 133 TO 0.5 MILE SOUTH OF ROUTE 91 |
QA Service Level | 1 (Verified on 08/02/2021) |
Sample Information
Sample Taken Date | 02/26/2022 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/14/2022 |
Sample type | Verification | A brief description of the sample | PG Asphalt Binder |
The quantity of what the sample constitutes | 1 Quart Can | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Vulcan Corona QC | Last name of sampler or witnessed by | Vulcan Corona QC |
Title of sampler | QC | Telephone number of sampler | |
Laboratory sample identification | 0161-22 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Corona Drum | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 58-16 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2022-02-26-5
DIME Test ID: 2022-02-26-5-9
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-04-12
Test Results
Phase: PAV residue
Input Type: Calculated
Tester's full name: Majid Essa
Date of test: 04/12/2022
Test Plate Diameter: 8 mm
Phase Angle (δ) (for the 10 cycles): 63.7 degree
(G*) x sin(δ)=: 1390 kPa
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/12/2022 ✔