Summary for Test 2022-03-31-10-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 215108
DEA: 07337604
EFIS: 0717000036
DIST-CO-RTE-PM07-LA-14-R28.9/R29.2
Award Date10/15/2020
Closeout Date05/04/2023
Work DescriptionREPLACE EXISTING STORM DRAIN, AND CONSTRUCT A COLLECTION SYSTEM.
Location DescriptionLOS ANGELES COUNTY IN AND NEAR SANTA CLARITA FROM 0.8 MILE NORTH OF PLACERITA CANYON ROAD UNDERCROSSING TO 0.5 MILE SOUTH OF GOLDEN VALLEY ROAD OVERCROSSING
QA Service Level1 (Verified on 02/24/2021)

Sample Information

Sample Taken Date03/31/2022 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/01/2022
Sample typeAcceptance A brief description of the sample3/4" HMA-A 105793 AAA IRW
The quantity of what the sample constitutes400 tons From where was the sample collectedManufacturer
First name of sampler or witnessed byHonesto Last name of sampler or witnessed byCastillo
Title of samplerMREA Telephone number of sampler
Laboratory sample identification22-0089 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAAA Irwindale Transportation Laboratory (TL) Number006565
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix NumberNot set

Test Details

DIME Sample ID: 2022-03-31-10
DIME Test ID: 2022-03-31-10-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2022-04-04

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Daniel Gomez
Date of test: 04/04/2022
Test procedure used?: Method A
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 2032.1 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 1933.3 g
Correction Factor (Percent by mass of HMA Specimen): 0.37 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 1000.4 F
Corrected Asphalt Binder Content: 4.49 %
General comments (publicly viewable) (Max 1000 characters):