Summary for Test 2022-03-23-26-2
Test performed: AASHTO T240-17Project Information
Project Identifiers | Project ID: 215188 DEA: 080F5434 EFIS: 0817000239 Permit Numbers: 0823NMC0369 |
---|---|
DIST-CO-RTE-PM | 08-RIV-I-15,SR-91-6.1-7.6 |
Award Date | 03/11/2020 |
Closeout Date | 06/05/2024 |
Work Description | I-15 ELC: 15/91 Express Lanes Connector Project (ELC) |
Location Description | Junction of I-15 and SR-91 in Corona, CA |
QA Service Level | 1 (Verified on 09/16/2020) |
Sample Information
Sample Taken Date | 03/23/2022 | Sample Unique Key | 26 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/25/2022 |
Sample type | Department Acceptance | A brief description of the sample | PG Asphalt Binder |
The quantity of what the sample constitutes | 1 Quart Can | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Idris | Last name of sampler or witnessed by | Najjar |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0189-22 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | RJ Noble-Corona | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-10 |
---|---|---|---|
Modified | Yes | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Lunday Thagard Company-World Oil - South Gate CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2022-03-23-26
DIME Test ID: 2022-03-23-26-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2022-04-01
Test Results
Is mass change based on one or two containers?: Two
Input Type: Measured
Tester's full name: Majid Essa
Date of test: 04/01/2022
Any material loss from containers during heating process/testing?: Yes
Mass of empty container #1: 167.938 grams
Mass of empty container #2: 172.985 grams
Mass of container #1 before test (m1i): 202.945 grams
Mass of container #2 before test (m2i): 208.013 grams
Mass of container #1 after test (m1f): 202.922 grams
Mass of container #2 after test (m2f): 207.994 grams
Average mass change: -0.060 percent
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/1/2022 ✔