Summary for Test 2022-02-02-44-3

Test performed: AASHTO T315-20

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date02/02/2022 Sample Unique Key44
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/08/2022
Sample typeVerification A brief description of the sampleTank 2026
The quantity of what the sample constitutes1 of 1 From where was the sample collectedManufacturer
First name of sampler or witnessed byGustavo Last name of sampler or witnessed byMoreno
Title of sampler Telephone number of sampler
Laboratory sample identification020222-010 Linked DIME Sample ID2022-02-02-23
The fabricator/manufacturer/facility nameSouth Gate, CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 70-10
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierLunday Thagard Company-World Oil - South Gate CA MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2022-02-02-44
DIME Test ID: 2022-02-02-44-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-03-30

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 03/28/2022
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 47.578 kPa
Phase Angle (δ) (for the 10 cycles): 45.0 degree
Complex Modulus (G*) (for the 10 measurements): 4757.854 kPa
Test Temperature (Specimen 1): 34.0 C
(G*) x sin(δ)=: 3364 kPa
General comments (publicly viewable) (Max 1000 characters): PAV

Test was verified on 3/30/2022