Summary for Test 2021-11-03-50-6
Test performed: CTM 206-October 2011Project Information
Project Identifiers | Project ID: 66666 DEA: APP EFIS: 0019000052 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 11/03/2021 | Sample Unique Key | 50 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 03/07/2022 |
Sample type | Aggregate Prequalification Program | A brief description of the sample | 1/2" Washed (1/2" X #4 CALTRANS SECTION 90) |
The quantity of what the sample constitutes | 3 Buckets | From where was the sample collected | Source |
First name of sampler or witnessed by | Kyle | Last name of sampler or witnessed by | Portlock |
Title of sampler | Lab Technician | Telephone number of sampler | 6195929623 |
Laboratory sample identification | Linked DIME Sample ID | 2021-11-03-9 | |
The fabricator/manufacturer/facility name | Hanson Aggregates | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Santee |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Half Inch Washed CALTRANS SECTION 90 1/2 INCH X NO. 4 | The fabricator/manufacturer designation for the sample | |
The plant number | 016 | A detailed description of where the material sample was collected | Stockpile |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-11-03-50
DIME Test ID: 2021-11-03-50-6
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 206-October 2011: Method of Test for Specific Gravity and Absorption of Coarse Aggregate
Test Release Date: 2022-03-29
Test Results
How will the aggregate be used?: aggregate base
Input Type: Calculated
Tester's full name: Larry Diaz
Date of test: 03/09/2022
% Water Absorbed: 1 %
Bulk Oven Dried Specific Gravity: 2.6
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/29/2022 ✔