Summary for Test 2022-03-21-15-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 214532 DEA: 07316904 EFIS: 0715000227 |
---|---|
DIST-CO-RTE-PM | 07-LA-1,2,5,10-Various |
Award Date | 01/24/2020 |
Closeout Date | 08/24/2022 |
Work Description | TUNNEL LIGHTING, MESSAGE SIGN SYSTEMS, RETAINING WALL & BUILDING WORK. |
Location Description | LOS ANGELES COUNTY AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 04/15/2020) |
Sample Information
Sample Taken Date | 03/21/2022 | Sample Unique Key | 15 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/23/2022 |
Sample type | Acceptance | A brief description of the sample | 3/8" HMA dike PG 70-10 |
The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Avo | Last name of sampler or witnessed by | Karajian |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | 22-0079 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Blue Diamond Material-Irwindale | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/8 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2022-03-21-15
DIME Test ID: 2022-03-21-15-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2022-03-24
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Daniel Gomez
Date of test: 03/24/2022
Test procedure used?: Method A
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 1588.9 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 1476.5 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 1000.4 F
Corrected Asphalt Binder Content: 7.07 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/24/2022 ✔