Summary for Test 2022-03-18-4-5
Test performed: ASTM A970-18Project Information
Project Identifiers | Project ID: 209820 DEA: 04297634 EFIS: 0415000040 COOP: 042548 |
---|---|
DIST-CO-RTE-PM | 04-ALA-84,680-17.9/21 |
Award Date | 02/19/2021 |
Closeout Date | Not set |
Work Description | ROUTE 84 WIDENING (4-LANE EXPRESSWAY) FROM I-680 TO PIGEON PASS, INCLUDING INTERSECTION, DRAINAGE IMPROVEMENTS AND UTILITY RELOCATION. |
Location Description | ALAMEDA COUNTY IN AND NEAR SUNOL, PLEASANTON, AND LIVERMORE ON ROUTE 84 FROM 0.1 MILE EAST OF ROUTE 680 TO 0.1 MILE SOUTH OF RUBY HILL DRIVE AND ON ROUTE 680 FROM 1.2 MILES SOUTH TO 1.8 MILES NORTH OF ROUTE 84 |
QA Service Level | 1 (Verified on 11/04/2019) |
Sample Information
Sample Taken Date | 03/18/2022 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/22/2022 |
Sample type | Quality Assurance | A brief description of the sample | #5 HRC 120 T Heads |
The quantity of what the sample constitutes | 556 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Brian | Last name of sampler or witnessed by | Murray |
Title of sampler | QA Inspector | Telephone number of sampler | 213 435 4055 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Headed Reinforcement Corp, Fountain Valley, CA | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L140-031-22 | Structure unique identifier | |
Structure name | Calaveras SB Bent 2 FTG ETC |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
---|---|---|---|
Rebar Heat Number(s) | 3110314 | Head Manufacturer Lot Number(s) | 10021114224 |
Rebar Size | #5 | Headed Bar Model Name | HRC 120 |
Size of Head | Full Size - 9x | Head Connection Type | Friction Weld |
Head Shape | Square | Rebar Manufacturer | CMC |
Head Manufacturer | Nucor | Head Fabricator | Nucor |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2022-03-18-4
DIME Test ID: 2022-03-18-4-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2022-03-28
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 03/24/2022
UTM: 400kip
Temperature: 72 f
Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
---|---|---|---|---|---|---|
1 | 4 | 0.31 | 28640 | 92387 | ok necking | spaine |
General comments (publicly viewable) (Max 1000 characters): ok necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 3/28/2022 ✔