Summary for Test 2022-01-28-23-11
Test performed: CTM 371-January 2005Project Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 01/28/2022 | Sample Unique Key | 23 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 11/30/2021 |
Sample type | Aggregate Prequalification Program | A brief description of the sample | 1/2" HMA-Type A-SP |
The quantity of what the sample constitutes | 36 box's of AC / 3 bags of cold feed /1 bag of RAP | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Ernesto | Last name of sampler or witnessed by | Marroquin |
Title of sampler | Sr Inspector | Telephone number of sampler | 2098125420 |
Laboratory sample identification | 1038V- 1285065255 | Linked DIME Sample ID | 2022-01-28-23 |
The fabricator/manufacturer/facility name | Granite Construction Company | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2022-01-28-23
DIME Test ID: 2022-01-28-23-11
Testing Lab: Garco Testing Laboratories
Test Method: CTM 371-January 2005: Method of Test for Resistance of Compacted Bituminous Mixture to Moisture Induced Damage (Moisture Content)
Test Release Date: 2022-03-23
Test Results
How many sample set dry and wet used?: 3
Input Type: Calculated
Tester's full name: Ernesto Marroquin
Date of test: 03/09/2022
Specimen Treatment: Treated
Average Dry Tensile Strength: 192 psi
Average Wet Tensile Strength: 179 psi
Tensile Strength Ratio: 93
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/23/2022 ✔