Summary for Test 2022-01-21-48-5

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 993183
DEA: 031H2704
EFIS: 0316000082
DIST-CO-RTE-PM03-YUB-70-R11.2/13.5
Award Date10/14/2021
Closeout DateNot set
Work DescriptionUPGRADE BRIDGE RAILS & CONSTRUCT CONCRETE MEDIAN BARRIER.
Location DescriptionYUBA COUNTY NEAR LINDA AND MARYSVILLE FROM 2.4 MILES SOUTH OF FEATHER RIVER BOULEVARD UNDERCROSSING TO THE YUBA RIVER BRIDGE AND OVERHEAD
QA Service Level1 (Verified on 08/16/2021)

Sample Information

Sample Taken Date01/21/2022 Sample Unique Key48
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/10/2022
Sample typeVerification A brief description of the sample1/2" HMA-A
The quantity of what the sample constitutes12 boxes of HMA, 2 cans of binder From where was the sample collectedSource
First name of sampler or witnessed byZack Last name of sampler or witnessed byMason
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameKnife River Construction Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix NumberNot set

Test Details

DIME Sample ID: 2022-01-21-48
DIME Test ID: 2022-01-21-48-5
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2022-03-22

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Julian Gonzales
Date of test: 02/16/2022
Test procedure used?: no data
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): no data %
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 5.10 %
General comments (publicly viewable) (Max 1000 characters): JMF 22-001

Test was verified on 3/22/2022