Summary for Test 2022-01-21-47-2

Test performed: AASHTO T209-12

Project Information

Project IdentifiersProject ID: 993183
DEA: 031H2704
EFIS: 0316000082
DIST-CO-RTE-PM03-YUB-70-R11.2/13.5
Award Date10/14/2021
Closeout DateNot set
Work DescriptionUPGRADE BRIDGE RAILS & CONSTRUCT CONCRETE MEDIAN BARRIER.
Location DescriptionYUBA COUNTY NEAR LINDA AND MARYSVILLE FROM 2.4 MILES SOUTH OF FEATHER RIVER BOULEVARD UNDERCROSSING TO THE YUBA RIVER BRIDGE AND OVERHEAD
QA Service Level1 (Verified on 08/16/2021)

Sample Information

Sample Taken Date01/21/2022 Sample Unique Key47
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/10/2022
Sample typeVerification A brief description of the sample1/2" Rap
The quantity of what the sample constitutes2 Bags of RAP From where was the sample collectedSupplier
First name of sampler or witnessed byZack Last name of sampler or witnessed byMason
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameKRC HALLWOOD Drum Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceKRC Hallwood
Aggregate Size Aggregate Source
RAP Stockpile Stockpile Size (tons)
Reclaimed Asphalt Pavement Mix NumberNot set

Test Details

DIME Sample ID: 2022-01-21-47
DIME Test ID: 2022-01-21-47-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2022-03-22

Test Results


Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Julian Gonzales
Date of test: 02/10/2022
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 1517.7 grams
Mass of oven-dry sample in air for Sample 1: 7345.5 grams
Mass of container filled with the sample and water for Sample 1: 8276.8 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 12.526
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters): JMF 22-001

Test was verified on 3/22/2022