Summary for Test 2016-04-28-11-9

Test performed: ASTM A416-15

Project Information

Project IdentifiersProject ID: 8196
DEA: 59912684
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work Description
Location Description
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date04/28/2016 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/10/2016
Sample typeQuality Assurance A brief description of the sample.5 Prestressing Strand
The quantity of what the sample constitutes65 From where was the sample collectedManufacturer
First name of sampler or witnessed byDon Last name of sampler or witnessed byHiranaga
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameSumiden Wire Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand CommentsUnknown
Reel/Coil/Pack Number(s) Number of Coils24
Group Number10844 Strand Diameter.5 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0530416, S0518416, S0516816, S0518516, S0517216, S0518116, S0518016, S0517716, S0518316, S0517616, S0283988, S0285457, S0285458 Mfg. Lot Number(s)NA
Manufacturer(s)Sumiden Wire

Test Details

DIME Sample ID: 2016-04-28-11
DIME Test ID: 2016-04-28-11-9
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2016-05-19

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 05/17/2016
UTM: 120KIP
Temperature: 70 F
Extensometers: E88766
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1SO518116S128973-30.15430264005428.51.65Brian

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 5/19/2016