Summary for Test 2022-02-10-10-2

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 213741
DEA: 07325704
EFIS: 0716000089
DIST-CO-RTE-PM07-LA-5-1.7
Award DateNot set
Closeout DateNot set
Work DescriptionBUILDING CONSTRUCTION IN LOS ANGELES COUNTY IN SANTA FE SPRINGS AT 14044 FREEWAY DRIVE.
Location DescriptionSanta Fe Springs, At 14044 Freeway Drive.
QA Service Level1 (Verified on 07/08/2019)

Sample Information

Sample Taken Date02/10/2022 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/15/2022
Sample typeQuality Assurance A brief description of the sample7/8" Nut
The quantity of what the sample constitutes384 From where was the sample collectedDistributor
First name of sampler or witnessed byBrian Last name of sampler or witnessed byMurray
Title of samplerQA Telephone number of sampler213 435 4055
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCordova Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL140-025-22 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)DL19106343 Nut Mfg. Lot Number(s)440322A
Washer Mfg. Lot Number(s)n/a Bolt Specificationn/a
Bolt Length(s)n/a Nut SpecificationSAE-J995-17
Washer Specificationn/a FinishPlain
Diameter/Size7/8" Bolt Mfg. Lot Numbern/a
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2022-02-10-10
DIME Test ID: 2022-02-10-10-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2022-03-28

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 03/14/2022
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11B440322A43671Nut Proof Loadspaine

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 3/28/2022