Summary for Test 2022-01-28-23-7
Test performed: CTM 371-January 2005
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.
Please click this
link
to view the corrected test.
Project Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 01/28/2022 | Sample Unique Key | 23 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 11/30/2021 |
Sample type | Aggregate Prequalification Program | A brief description of the sample | 1/2" HMA-Type A-SP |
The quantity of what the sample constitutes | 36 box's of AC / 3 bags of cold feed /1 bag of RAP | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Ernesto | Last name of sampler or witnessed by | Marroquin |
Title of sampler | Sr Inspector | Telephone number of sampler | 2098125420 |
Laboratory sample identification | 1038V- 1285065255 | Linked DIME Sample ID | 2022-01-28-23 |
The fabricator/manufacturer/facility name | Granite Construction Company | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2022-01-28-23
DIME Test ID: 2022-01-28-23-7
Testing Lab: Garco Testing Laboratories
Test Method: CTM 371-January 2005: Method of Test for Resistance of Compacted Bituminous Mixture to Moisture Induced Damage (Moisture Content)
Test Release Date: 2022-03-09
Test Results
How many sample set dry and wet used?: 4
Input Type: Calculated
Tester's full name: Ernesto Marroquin
Date of test: 01/28/2022
Specimen Treatment: Treated
Average Dry Tensile Strength: 175 psi
Average Wet Tensile Strength: 166 psi
Tensile Strength Ratio: 95
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/9/2022 ✔
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.