Summary for Test 2022-01-21-2-1
Test performed: ASTM A416-18Project Information
Project Identifiers | Project ID: 214951 DEA: 120K0234 EFIS: 1214000100 |
---|---|
DIST-CO-RTE-PM | 12-ORA-5-17.1/18.9 |
Award Date | 09/23/2020 |
Closeout Date | Not set |
Work Description | South County Improvement Project (Phase 3 - El Toro/Alicia) WIDEN FREEWAY AND BRIDGES, RECONSTRUCT BRIDGE AND WALLS. |
Location Description | ORANGE COUNTY IN MISSION VIEJO, LAGUNA HILLS, LAGUNA WOODS AND LAKE FOREST FROM 0.4 MILE SOUTH OF ALICIA PARKWAY OVERCROSSING TO 0.2 MILE NORTH OF EL TORO ROAD UNDERCROSSING |
QA Service Level | 1 (Verified on 10/01/2020) |
Sample Information
Sample Taken Date | 01/21/2022 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 01/26/2022 |
Sample type | Department Acceptance | A brief description of the sample | Prestressing Strand |
The quantity of what the sample constitutes | (1 pack) .6"Ø 8,900 ft. Long | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Paul | Last name of sampler or witnessed by | Shrestha |
Title of sampler | LA METS QA Inspector | Telephone number of sampler | 4242987781 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | ConFab | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L108-001-22 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM4 - Prestressing Strand | Comments | |
---|---|---|---|
Reel/Coil/Pack Number(s) | S335592-2 | Number of Coils | 1 |
Group Number | Strand Diameter | .6 in | |
Grade | 270 | Strand Specification | ASTM A 416 |
Heat Number(s) | S0519020-2 | Mfg. Lot Number(s) | S335592-2 |
Manufacturer(s) | Sumiden |
Test Details
DIME Sample ID: 2022-01-21-2
DIME Test ID: 2022-01-21-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2022-03-02
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 03/02/2022
UTM: 120kip
Temperature: 72 f
Extensometers: E88766
Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | S0519020-2 | S335592-2 | 0.213 | 59731 | 55214.4 | 28.5 | 1.76 | bewing |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 3/2/2022 ✔