Summary for Test 2022-03-01-4-1
Test performed: CTM 231-March 2013Project Information
Project Identifiers | Project ID: 214436 DEA: 074V1604 EFIS: 0719000193 |
---|---|
DIST-CO-RTE-PM | 07-LA-126,126-31.3,R5.0/R5.3 |
Award Date | 03/16/2021 |
Closeout Date | 10/06/2022 |
Work Description | RESTORE EXISTING BEST MANAGEMENT PRACTICE (BMP) |
Location Description | LOS ANGELES COUNTY AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 05/04/2021) |
Sample Information
Sample Taken Date | 03/01/2022 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/01/2022 |
Sample type | Acceptance | A brief description of the sample | Soil for subgrade |
The quantity of what the sample constitutes | 841 yd2 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Rosauro | Last name of sampler or witnessed by | Nogoy |
Title of sampler | TEC | Telephone number of sampler | 2137939321 |
Laboratory sample identification | 22-0375 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | O Donnell Construction | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Various locations at subgrade | |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2022-03-01-4
DIME Test ID: 2022-03-01-4-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2022-03-01
Test Results
Method Type:: Direct Read
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Rosauro Nogoy
Date of test: 03/01/2022
Gage No.: 60202
Test No.: 1
Nuclear By: Rosauro Nogoy
Non-Bias Plan No.: 2
Depth: 8 in
Material No.: Imported Material
Material Type: Aggregate Base
Impact By: Rosauro Nogoy
Standard Count Density: 2376 g/cc
Count or Density 1: 2.15 g/cc
Count or Density 2: 2.13 g/cc
Count or Density 3: 2.17 g/cc
Standard Count Moisture: 629 g/cc
Moisture Count 1: 0.12 g/cc
Moisture Count 2: 0.11 g/cc
Moisture Count 3: 0.12 g/cc
Sum of Count or Density: 6.45 g/cc
Average of Count or Density: 2.15 g/cc
Sum of Moisture Count: 0.35 g/cc
Average of Moisture Count: 0.12 g/cc
Calculated Percent Relative Compaction: 99.1 %
Reported Percent Relative Compaction: 99 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/1/2022 ✔