Summary for Test 2022-03-01-1-4
Test performed: ASTM D5329-16Project Information
Project Identifiers | Project ID: 8802 DEA: RR-ARB21 EFIS: RR-ARB21 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special Project for Round Robin of Asphalt Rubber Binder 2021 |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 03/01/2022 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/01/2022 |
Sample type | Informational | A brief description of the sample | rubber binder |
The quantity of what the sample constitutes | 1 gallon can | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Akira | Last name of sampler or witnessed by | Akira |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | National Brending Company | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
---|---|---|---|
Performance Grade | PG 64-16 | Lot number | |
Sublot number | Asphalt Rubber Binder Mix Number |
Test Details
DIME Sample ID: 2022-03-01-1
DIME Test ID: 2022-03-01-1-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2022-03-01
Test Results
Input Type: Measured
Tester's full name: Juan Gomez
Date of test: 03/01/2022
Temperature: 25 C
Final Dial reading (F1): 75 mm
Ball Penetration (P1): 5 mm
Final Dial reading (F2): 76 mm
Ball Penetration (P2): 6 mm
Final Dial reading (F3): 78 mm
Ball Penetration (P3): 4 mm
Resilience 1: 30 %
Resilience 2: 30 %
Resilience 3: 26 %
Average Resilience: 29 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/1/2022 ✔