Summary for Test 2022-03-01-1-2
Test performed: ASTM D5329-16
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.
Please click this
link
to view the corrected test.
Project Information
Project Identifiers | Project ID: 8802 DEA: RR-ARB21 EFIS: RR-ARB21 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special Project for Round Robin of Asphalt Rubber Binder 2021 |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 03/01/2022 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/01/2022 |
Sample type | Informational | A brief description of the sample | rubber binder |
The quantity of what the sample constitutes | 1 gallon can | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Akira | Last name of sampler or witnessed by | Akira |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | National Brending Company | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
---|---|---|---|
Performance Grade | PG 64-16 | Lot number | |
Sublot number | Asphalt Rubber Binder Mix Number |
Test Details
DIME Sample ID: 2022-03-01-1
DIME Test ID: 2022-03-01-1-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2022-03-01
Test Results
Input Type: Measured
Tester's full name: Juan Gomez
Date of test: 03/01/2022
Temperature: 25 C
Final Dial reading (F1): 86 mm
Ball Penetration (P1): 5 mm
Final Dial reading (F2): 86 mm
Ball Penetration (P2): 6 mm
Final Dial reading (F3): 85 mm
Ball Penetration (P3): 3 mm
Resilience 1: 19 %
Resilience 2: 20 %
Resilience 3: 18 %
Average Resilience: 19 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/1/2022 ✔
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.