Summary for Test 2022-02-23-2-4
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 215784 DEA: 051G2604 EFIS: 0514000131 |
---|---|
DIST-CO-RTE-PM | 05-SCR-17-9.1/9.9 |
Award Date | 08/11/2021 |
Closeout Date | 02/14/2024 |
Work Description | CONSTRUCT STRUCTURAL CONCRETE BRIDGE AND ELECTRIFIED BARRIER SYSTEMS. |
Location Description | SANTA CRUZ COUNTY NEAR SCOTTS VALLEY FROM 0.6 MILE SOUTH OF LAUREL ROAD TO 0.2 MILE NORTH OF LAUREL ROAD |
QA Service Level | 1 (Verified on 06/21/2021) |
Sample Information
Sample Taken Date | 02/23/2022 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/25/2022 |
Sample type | Quality Assurance | A brief description of the sample | #5 X 1'-6" Ultimate Welded Hoops |
The quantity of what the sample constitutes | 24 total | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Juan | Last name of sampler or witnessed by | Garcia |
Title of sampler | QA | Telephone number of sampler | 17029172503 |
Laboratory sample identification | L115-016-22 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | T.N.T Rebar Company | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L115-016-22 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 3500022537 |
Hoop Manufacturer Lot Number(s) | Lots - 1, 4, 10, 15, 20 and 23 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | #5 |
Diameter of Hoop | 1'-6" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Nucor Seattle |
Welding Company | TNT Rebar Company | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2022-02-23-2
DIME Test ID: 2022-02-23-2-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2022-03-03
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 02/28/2022
UTM: 400kip
Temperature: 72 f
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1 | 4 | 5/16mm | 0.31 | 28871.98 | 93135 | ok necking | spaine |
General comments (publicly viewable) (Max 1000 characters): ok necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 3/3/2022 ✔