Summary for Test 2016-03-30-2-1
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 209950 DEA: 080N56U4 EFIS: 0813000176 |
---|---|
DIST-CO-RTE-PM | 08-SBD-40-R94.7/R99.7 |
Award Date | 01/22/2015 |
Closeout Date | 09/17/2018 |
Work Description | BRIDGE REPLACEMENTS. |
Location Description | SAN BERNARDINO COUNTY NEAR ESSEX AT HALLER WASH BRIDGE AT ROJO WASH BRIDGE AND AT CLIPPER VALLEY WASH BRIDGE |
QA Service Level | 1 (Verified on 04/29/2015) |
Sample Information
Sample Taken Date | 03/30/2016 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/04/2016 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | LEONARD | Last name of sampler or witnessed by | ROMERO |
Title of sampler | STRUCTURE REP | Telephone number of sampler | Unknown |
Laboratory sample identification | 907-39 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | ROBERTSONS MIX | Transportation Laboratory (TL) Number | 040416639 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
Structure name | Unknown |
Material Information
Material Type | Concrete | The concrete mix design number | RRM15025 |
---|---|---|---|
The truck number from where the sample was collected | 1218 | The batch plant ticket number from where the sample was collected | 1419485 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | PLANT |
A detailed description of where the material sample was collected | LOAD 2 | Where the material sample would have been placed if not sampled | BARRIER RAIL SOUTH SIDE ABUTMENT 1 |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2016-03-30-2
DIME Test ID: 2016-03-30-2-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-04-27
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 04/27/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 161340 lb
Maximum load on cylinder 2: 168450 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 5707.1 psi
Compressive strength of cylinder 2: 5958.6 psi
Compressive strength (to nearest 10 psi): 5830 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/27/2016 ✔