Summary for Test 2022-02-08-19-2
Test performed: AASHTO T240-17Project Information
Project Identifiers | Project ID: 55556 DEA: OCR EFIS: OCR |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Oregon Corp. Research. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 02/08/2022 | Sample Unique Key | 19 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/14/2022 |
Sample type | Proficiency | A brief description of the sample | ASPHALT BINDER |
The quantity of what the sample constitutes | 1 OF 1 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | KEVIN | Last name of sampler or witnessed by | MCKINNEY |
Title of sampler | ASPHALT TECHNOLOGIST | Telephone number of sampler | 775-835-6366 |
Laboratory sample identification | OCTG SAMPLE ID 322 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | PNAC LLC, Marathon Petroleum | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 70-34 M |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | PNAC LLC - Fernley NV | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2022-02-08-19
DIME Test ID: 2022-02-08-19-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2022-02-18
Test Results
Is mass change based on one or two containers?: One
Input Type: Measured
Tester's full name: Ruben Macias
Date of test: 02/16/2022
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 174.7 grams
Mass of container #1 before test (m1i): 209.45 grams
Mass of container #1 after test (m1f): 209.42 grams
Average mass change: -0.086 percent
General comments (publicly viewable) (Max 1000 characters): MASS CHANGE RUN PAV 100C
Test was verified on 2/18/2022 ✔