Summary for Test 2022-02-14-2-8

Test performed: ASTM B499-09r21

Project Information

Project IdentifiersProject ID: 214579
DEA: 010B0904
EFIS: 0100020444
DIST-CO-RTE-PM01-DN-101-8.2/8.7
Award Date04/21/2020
Closeout DateNot set
Work DescriptionPanther Creek & Hunter Creek Bridges
Location DescriptionDEL NORTE COUNTY NEAR KLAMATH AT PANTHER CREEK BRIDGE AND AT HUNTER CREEK BRIDGE
QA Service Level1 (Verified on 03/02/2020)

Sample Information

Sample Taken Date02/14/2022 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/16/2022
Sample typeQuality Assurance A brief description of the sampleASTM F-A325 Fastener
The quantity of what the sample constitutes60 From where was the sample collectedManufacturer
First name of sampler or witnessed byCharles C Last name of sampler or witnessed byFranco
Title of samplerQA Inspector Telephone number of sampler858-583-9270
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameFontana Gruppo Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameGilman Street Pedestrian Bridge

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)L1414679
Heat Number(s)10565200 Nut Mfg. Lot Number(s)34998-212315
Washer Mfg. Lot Number(s)0721-878 Bolt SpecificationASTM F3125-A325
Bolt Length(s)1-1/2" Nut SpecificationA563-DH
Washer SpecificationF436-1 FinishHDG
Diameter/Size3/4" Bolt Mfg. Lot NumberL973MI
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2022-02-14-2
DIME Test ID: 2022-02-14-2-8
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2022-02-23

Test Results


Input Type: Calculated
Tester's full name: Steven Paine
Date of test: 02/17/2022
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: L973M1
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: A325 USA LE
Size: .75 in
Bolt Length: 1.5 in
Measurement Average: 3.01 mils
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/23/2022