Summary for Test 2022-02-14-2-1
Test performed: ASTM F606-21Project Information
Project Identifiers | Project ID: 214579 DEA: 010B0904 EFIS: 0100020444 |
---|---|
DIST-CO-RTE-PM | 01-DN-101-8.2/8.7 |
Award Date | 04/21/2020 |
Closeout Date | Not set |
Work Description | Panther Creek & Hunter Creek Bridges |
Location Description | DEL NORTE COUNTY NEAR KLAMATH AT PANTHER CREEK BRIDGE AND AT HUNTER CREEK BRIDGE |
QA Service Level | 1 (Verified on 03/02/2020) |
Sample Information
Sample Taken Date | 02/14/2022 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/16/2022 |
Sample type | Quality Assurance | A brief description of the sample | ASTM F-A325 Fastener |
The quantity of what the sample constitutes | 60 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Charles C | Last name of sampler or witnessed by | Franco |
Title of sampler | QA Inspector | Telephone number of sampler | 858-583-9270 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Fontana Gruppo | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Gilman Street Pedestrian Bridge |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | L1414679 |
---|---|---|---|
Heat Number(s) | 10565200 | Nut Mfg. Lot Number(s) | 34998-212315 |
Washer Mfg. Lot Number(s) | 0721-878 | Bolt Specification | ASTM F3125-A325 |
Bolt Length(s) | 1-1/2" | Nut Specification | A563-DH |
Washer Specification | F436-1 | Finish | HDG |
Diameter/Size | 3/4" | Bolt Mfg. Lot Number | L973MI |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2022-02-14-2
DIME Test ID: 2022-02-14-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2022-02-23
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 02/17/2022
UTM: 450kip
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1A | L973M1 | 53095 | Nut Proof Load | spaine |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 2/23/2022 ✔