Summary for Test 2022-01-10-42-1

Test performed: AASHTO T51-13

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date01/10/2022 Sample Unique Key42
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/10/2022
Sample typeVerification A brief description of the sampleAsphalt Binder Sample
The quantity of what the sample constitutes2 OF 2 quart cans, split sample From where was the sample collectedSource
First name of sampler or witnessed byTom Last name of sampler or witnessed byReneau
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID2022-01-10-40
The fabricator/manufacturer/facility nameWESTERN EMULSIONS WHITE CITY OR Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
ModifiedNo Lot number
Sublot number Tank number
Time of sample0800 HMA Supplier
Certified Asphalt SupplierWestern Emulsion - White City Emulsion Plant - White City OR MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2022-01-10-42
DIME Test ID: 2022-01-10-42-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2022-02-15

Test Results


Is a normal test obtainable?: Yes
Number of replicates tested: One
Input Type: Measured
Tester's full name: Ruben Macias
Date of test: 02/14/2022
Ductility of test #1 (D1): 150 cm
Ductility of sample: 150 cm
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications

Test was verified on 2/15/2022