Summary for Test 2022-01-20-54-2
Test performed: CTM 217-June 2011Project Information
Project Identifiers | Project ID: 215734 DEA: 024H0104 EFIS: 0218000068 |
---|---|
DIST-CO-RTE-PM | 02-PLU-70-78.3/90.3 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Not set |
Location Description | Not set |
QA Service Level | 1 (Verified on 07/08/2021) |
Sample Information
Sample Taken Date | 01/20/2022 | Sample Unique Key | 54 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/21/2022 |
Sample type | Preliminary | A brief description of the sample | Soil |
The quantity of what the sample constitutes | 1 bag representing 0.5 mile of drainage ditch | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Darrell | Last name of sampler or witnessed by | Valasek |
Title of sampler | MREA | Telephone number of sampler | |
Laboratory sample identification | D78997 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Unknown | Transportation Laboratory (TL) Number | 824598 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | 02-PLU-70-84.15, South ditch, 0.5 to 1.5 ft depth | |
Where the material sample would have been placed if not sampled | In situ |
Test Details
DIME Sample ID: 2022-01-20-54
DIME Test ID: 2022-01-20-54-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2022-02-28
Test Results
Number of tests: 3
Input Type: Measured
Tester's full name: Colt Sweeny
Date of test: 02/01/2022
Temperature correction: 0
Temperature of solution: 23.5
Clay reading (test 1): 6.2
Sand reading (test 1): 3.8
Clay reading (test 2): 6.3
Sand reading (test 2): 3.8
Clay reading (test 3): 6.3
Sand reading (test 3): 3.8
Sand equivalent (test 1): 62
Sand equivalent (test 2): 61
Sand equivalent (test 3): 61
Sand equivalent before temperature correction: 62
Sand equivalent after temperature correction: 62
General comments (publicly viewable) (Max 1000 characters): SE = 61
Test was verified on 2/28/2022 ✔