Summary for Test 2022-01-20-51-2
Test performed: CTM 217-June 2011Project Information
Project Identifiers | Project ID: 215734 DEA: 024H0104 EFIS: 0218000068 |
---|---|
DIST-CO-RTE-PM | 02-PLU-70-78.3/90.3 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Not set |
Location Description | Not set |
QA Service Level | 1 (Verified on 07/08/2021) |
Sample Information
Sample Taken Date | 01/20/2022 | Sample Unique Key | 51 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/21/2022 |
Sample type | Preliminary | A brief description of the sample | Soil |
The quantity of what the sample constitutes | 1 Bag representing .5 mile of drainage ditch | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Darrell | Last name of sampler or witnessed by | Valasek |
Title of sampler | MREA | Telephone number of sampler | |
Laboratory sample identification | D78993 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Unknown | Transportation Laboratory (TL) Number | 824594 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | 02-PLU-70 82.15-south side ditch- 0.5-1.5 ft. depth | |
Where the material sample would have been placed if not sampled | 02 PLU 70 |
Test Details
DIME Sample ID: 2022-01-20-51
DIME Test ID: 2022-01-20-51-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2022-02-17
Test Results
Number of tests: 3
Input Type: Measured
Tester's full name: Karen Rios Dorado
Date of test: 01/28/2022
Temperature correction: 0
Temperature of solution: 21.5
Clay reading (test 1): 7.7
Sand reading (test 1): 3.2
Clay reading (test 2): 7.7
Sand reading (test 2): 3.1
Clay reading (test 3): 7.9
Sand reading (test 3): 3.3
Sand equivalent (test 1): 42
Sand equivalent (test 2): 41
Sand equivalent (test 3): 42
Sand equivalent before temperature correction: 42
Sand equivalent after temperature correction: 42
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/17/2022 ✔