Summary for Test 2022-02-01-23-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 02/01/2022 | Sample Unique Key | 23 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/01/2022 |
Sample type | Aggregate Prequalification Program | A brief description of the sample | RAP - Ign 2 |
The quantity of what the sample constitutes | JMF Prequalification | From where was the sample collected | Source |
First name of sampler or witnessed by | Mack | Last name of sampler or witnessed by | Reardon |
Title of sampler | QC Technician | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Vulcan Materials - Pleasanton | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Reclaimed Asphalt Pavement | RAP Source | Vulcan Materials Pleasanton |
---|---|---|---|
Aggregate Size | Aggregate Source | ||
RAP Stockpile | Stockpile Size (tons) | ||
Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2022-02-01-23
DIME Test ID: 2022-02-01-23-1
Testing Lab: Vulcan Materials Company - Pleasanton
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2022-02-14
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Mack Reardon
Date of test: 02/01/2022
Test procedure used?: no data
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 1.90 %
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 5.35 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/14/2022 ✔