Summary for Test 2022-02-05-8-1
Test performed: ASTM C39-21Project Information
Project Identifiers | Project ID: 214671 DEA: 07303904 EFIS: 0714000044 |
---|---|
DIST-CO-RTE-PM | 07-LA-10-31.2/37.2 |
Award Date | 11/25/2020 |
Closeout Date | 10/11/2023 |
Work Description | LANE REPLACEMENT |
Location Description | LOS ANGELES COUNTY IN BALDWIN PARK AND WEST COVINA FROM 0.1 MILE EAST OF THE 10/605 SEPARATION TO 0.3 MILE WEST OF CITRUS STREET OVERCROSSING |
QA Service Level | 1 (Verified on 01/21/2021) |
Sample Information
Sample Taken Date | 02/05/2022 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/05/2022 |
Sample type | Quality Assurance | A brief description of the sample | A set of 2 LCB RS cylinders |
The quantity of what the sample constitutes | 500 CY | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Edmond | Last name of sampler or witnessed by | Jabbour |
Title of sampler | Field Materials Tester | Telephone number of sampler | 9092398226 |
Laboratory sample identification | 22-0213 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Security Paving Burbank Batch Plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | G322LRS271 |
---|---|---|---|
The truck number from where the sample was collected | Load 11 | The batch plant ticket number from where the sample was collected | 183757 |
Concrete batch plant | Security Paving Burbank Batch Plant | The fabricator/manufacturer designation for the sample | |
A detailed description of where the material sample was collected | Concrete from wheelbarrow | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2022-02-05-8
DIME Test ID: 2022-02-05-8-1
Testing Lab: Kleinfelder, Incorporated - Los Angeles
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2022-02-14
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Edmond Jabbour
Date of test: 02/12/2022
Apparent mass of submerged cylinder 1: 0 lb
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 5.99 in
Maximum load on cylinder 1: 110720 lb
Maximum load on cylinder 2: 116700 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.18 in^2
Compressive strength (to nearest 10 psi): 4020 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters): EB 10 Fwy #4 Lane - Sampled at STA: 1755+50
Test was verified on 2/14/2022 ✔