Summary for Test 2022-01-30-2-1
Test performed: CTM 524-March 2013Project Information
Project Identifiers | Project ID: 214573 DEA: 073096U4 EFIS: 0719000091 |
---|---|
DIST-CO-RTE-PM | 07-LA-210-R0.0/R9.7 |
Award Date | 04/03/2020 |
Closeout Date | 06/06/2024 |
Work Description | PLACE CONCRETE PAVEMENT, BARRIER, HMA, DRAINAGE, AND ELECTRICAL. |
Location Description | LOS ANGELES COUNTY IN LOS ANGELES FROM INTERSTATE 5 TO WHEATLAND AVENUE UNDERCROSSING |
QA Service Level | 1 (Verified on 06/05/2020) |
Sample Information
Sample Taken Date | 01/30/2022 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/30/2022 |
Sample type | Per Request | A brief description of the sample | A set of 3 JPCP RSC beams |
The quantity of what the sample constitutes | Per 500 CY | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Edmond | Last name of sampler or witnessed by | Jabbour |
Title of sampler | Field Materials Tester | Telephone number of sampler | 9092398226 |
Laboratory sample identification | 22-0167 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Flatiron Plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | 3215-JPCPRSC-12 |
---|---|---|---|
The truck number from where the sample was collected | Load 113 | The batch plant ticket number from where the sample was collected | 111 |
Concrete batch plant | Flatiron Plant | The fabricator/manufacturer designation for the sample | |
A detailed description of where the material sample was collected | See Below Notes | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2022-01-30-2
DIME Test ID: 2022-01-30-2-1
Testing Lab: Kleinfelder, Incorporated - Los Angeles
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2022-02-10
Test Results
Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Calculated
Tester's full name: Michael Magana
Date of test: 02/09/2022
Identification number: 22-0167
Width of specimen: 6.0625 inch
Width of specimen 2: 6.125 inch
Width of specimen 3: 6 inch
Depth of specimen: 6.0625 inch
Depth of specimen 2: 6.0625 inch
Depth of specimen 3: 6 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 720 lb
Maximum load applied 2: 700 lb
Maximum load applied 3: 710 lb
Curing history and apparent moisture condition of the specimen: Sand Pit / Water Tank
If specimen was capped, ground or if leather shims were used: N/A
Defects in specimen, including numbers of beams discarded during test: N/A
Age of specimen: 10 days
Age of specimen in hours: no data
Modulus of rupture: 720 psi
Modulus of rupture 2: 700 psi
Modulus of rupture 3: 710 psi
Modulus of rupture average: 710 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/10/2022 ✔