Summary for Test 2016-03-14-5-3
Test performed: ASTM A416-15Project Information
Project Identifiers | Project ID: 8196 DEA: 59912684 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | |
Location Description | |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 03/14/2016 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/22/2016 |
Sample type | Quality Assurance | A brief description of the sample | .6in Prestressing Strand |
The quantity of what the sample constitutes | 120 | From where was the sample collected | Source |
First name of sampler or witnessed by | Don | Last name of sampler or witnessed by | Hiranaga |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Sumiden Wire | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM4 - Prestressing Strand | Comments | Unknown |
---|---|---|---|
Reel/Coil/Pack Number(s) | S333623-3, S377385-5, S333625-1, S377388-1, S333630-6, S377393-3, S333633-5, S333636-5, S333639-3, S333639-4, S333653-6, S333683-4, S333687-2, S333688-3, S333691-2, S333692-3, S333692-4, S333696-3, S333696-5, S333699-5, S333700-2, S333701-2, S333702-3 | Number of Coils | Unknown |
Group Number | 10841 | Strand Diameter | .6 in |
Grade | 270 | Strand Specification | ASTM A 416 |
Heat Number(s) | S0585015, S0584915, S0584115, S0584515, S0584415, S0595115, S0526315, S0585115, S0533115-2, S0525415, S0518616, S0285106, S0285101, S0285103, S0285108, S0530116, S0591315, S0592115, S0585215, S0584815, S0584215, S0584615, S0585315, S0584315, S0525715-2, S0525515, S0526215, S0525215, S0525015-2 | Mfg. Lot Number(s) | 10841 |
Manufacturer(s) | Sumiden Wire |
Test Details
DIME Sample ID: 2016-03-14-5
DIME Test ID: 2016-03-14-5-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2016-04-06
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 03/30/2016
UTM: 120KIP
Temperature: 70 F
Extensometers: E88766
Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | SO584915 | S333625-1 | 0.21 | 60800 | 56047 | 29 | 1.8600000000000001 | Brian |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 4/6/2016 ✔